Some Ideas on Geyser Installation You Need To Know

Wiki Article

The Ultimate Guide To Geyser Installation

Table of ContentsWhat Does Geyser Installation Do?Facts About Geyser Installation RevealedThe smart Trick of Geyser Installation That Nobody is DiscussingGetting My Geyser Installation To Work
In this short article I will certainly describe the regular fundamental requirements of a noise, modern high stress, horizontal setup. The complying with summary connects to a modern high stress (400/600Kpa) system normally made by Kwikot South Africa.

geyser installationgeyser installation


Less usual are old reduced pressure systems (100kpa) open pipe or "Latco" type systems. Understand that the parts are NOT interchangeable between both unique systems - High stress and also Reduced pressure! It is feasible to eliminate an old low pressure system and also change it with a contemporary high pressure system however - you get a brand-new high stress geyser as well as mount it according to the existing spec.



The geyser rests in a tray made of plastic (frequently red) or tin plate. I favor the plastic ones.

Considering that June 2001, the drip tray is not optional - its obtained to be there and there has to be a drain pipe for it! The drainpipe is a 50mm PVC waste pipeline that drains pipes the tray by piping the water out the house (geyser installation).

The Greatest Guide To Geyser Installation

The next most visible attribute would be the. These are small brass parts installed at the end of a 30cm size of pipe. Both vacuum cleaner breakers stand vertically concerning 30cm above the geyser. These are very important, as they quit water siphoning out the hot spring when the cool supply is quit.

Bear in mind that vacuum cleaner breakers are a sensibly brand-new demand - there are still thousands of old HP systems out there without vacuum breakers as well as I am yet to see one collapse. Simply because I have not seen it doesn't imply it's not happening!

The cool water side is the side that straight connects to the drain penis and gets in the geyser at the base. After the shut down valve you would normally discover a Stress Control Valve (PCV). There are a number of different kinds, mostly made from brass yet some are made of plastic.

This is where the PCV releases stress and also this is the pipe that often leaks. Do not panic if you can not discover the PCV following to the hot spring - it may be totaled 10 metres away, usually in a much more obtainable location on a wall surface outside. Often it remains in a little plastic box exterior.

The Geyser Installation Ideas

This is a crucial part that should never be tinkered or 'repaired'. This shutoff should have a steel (copper or steel) pipeline linked to it and also the pipeline need to lead directly out the building. This air vent pipe is an important safety function of the read entire system. It must be made from copper or steel - plastic.

The T&P valve is the least why not try this out optional part - it needs to exist! - The weight of the geyser must be effectively supported on the roof covering trusses - a minimum of two supports under the 'feet' of the hot spring. If it looks unsteady obtain a plumbing technician to examine it out.

The hot spring has to be earthed! I have actually seen lots of geysers with the earth cable inapplicable. All the copper pipelines have to also be earthed and also bound to the hot spring earth.


Once more, these are usually simply left existing next to the hot spring. There are essentially just 2 primary thermostat types - the contemporary round "Kwiktherm" in more recent Kwikot geysers as well as the VK (rectangular block) key in older geysers as well as in some newer non-Kwikot units. The hot spring might be fed (chilly water) with polcop (plastic) pipe - approximately the shut down shutoff, yet the pipe into as well as out of the hot spring have to be copper or galvanized steel.

The Basic Principles Of Geyser Installation

geyser installationgeyser installation


The hot water side must be copper, steel or appropriately ranked (70) plastic or composite pipe. Keep in mind that you should contend least 1m of copper/steel pipe out the hot spring - you may not link plastic (composite) pipeline directly to the geyser. As above, the PCV and also T&P need to be made from copper or steel - especially the air vent out of the T&P valve.

geyser installationgeyser installation


I have seen a variety of installments where the installer has just run a short size of 22mm copper into the drip tray with the idea being that the T&P can vent straight into the drip tray. An idea the original source due to the fact that the warm (100 +) water/steam thaws the drip tray and the PVC drainpipe pipe.

The PCV is usually above the hot spring and the cool water flows down right into the geyser. This is rather vital due to the fact that it forms an anti-syphon loophole that protects against the geyser from draining pipes back via the inlet in case of a water system failing. If you obtain warm water appearing your cool faucets when the supply of water fails then this is not working correctly.